Series of common burner |
|
| Natural gas burner |
 |
|
|
|
|
|
|
|
Blowing mechatronics fuel gas burner |
Fission fuel gas burner |
No air blow gas burner |
Long flame fuel gas burner |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Series of metallurgy combustion apparatus |
|
|
|
|
|
Blowing mechatronics fuel gas burner |
|
|
|
- This burner is a blowing mechatronics fuel gas burner.
- It employs a method that combines the in-band long position and wind scatter, and it can make sure the safe, stable and high efficient combustion.
- Automatic control system contains: segmental fire type (air segmental fire control, frequency conversion segmental fire control), air sintering accommodation proportion type, frequency conversion accommodation type, and touch screen digital frequency conversion accommodation proportion type. It could meet different demands of the users.
- Types of combustion: natural gas, city gas, liquefied petroleum gas and so on.
- There is no limitation on the heating value of burning gas and the pressure. Users can make a request as long as they order the goods.
- We can also outfit some functions according the users' demands, such as flameout protection,processing ignition,chase leaks, over temperature and excessive pressure protection and so on.
- Without the automatic system, manual operation can make normal combustion, and the accommodation is very easy.
|
|
|
Other series |
|
|
|
|
|
| |
|
|
| |
|
| Type |
Design power
(KW) |
Design fuel gas quantity
(Nm3/h) |
Fuel gas quantity
(Nm3/h) |
Power regulation range(KW) |
Flame diameter(mm) |
Flame length(mm) |
Electromotor power
(KW) |
Voltage
(V) |
| Long flame |
Short flame |
Long flame |
Short flame |
| GCDN20 |
200 |
20 |
12-34 |
118-328 |
150 |
250 |
800 |
500 |
0.37 |
220 |
| GCDN40 |
400 |
40 |
19-53 |
185-523 |
180 |
300 |
1000 |
600 |
0.37 |
220 |
| GCDN60 |
600 |
61 |
25-85 |
248-838 |
200 |
350 |
1200 |
700 |
0.75 |
380 |
| GCDN100 |
1000 |
100 |
35-144 |
350-1426 |
220 |
360 |
1400 |
800 |
1.5 |
380 |
| GCDN150 |
1500 |
150 |
60-202 |
590-2000 |
260 |
500 |
2000 |
1200 |
2.2 |
380 |
| GCDN250 |
2500 |
250 |
66-313 |
657-3100 |
300 |
600 |
2600 |
1500 |
7.5 |
380 |
| GCDN300 |
3000 |
300 |
110-404 |
1085-4000 |
400 |
800 |
3000 |
2000 |
11 |
380 |
|
| |
|
|
| |
|
- This burner can be applied to blowing –fission fuel gas burner with high,middle,and low pressure and high, middle, and low heating value fuel.
- Base organization is made up of multi-in-band pipe and air distribution machine. In this way, it can make the combustion complete and stable.
- Automatic system contains various kinds of control modes, such as segmental fire type (air segmental fire control, frequency conversion segmental fire control), air sintering accommodation proportion type, frequency conversion accommodation type, touch screen digital frequency conversion accommodation proportion type and so on.
- There is no limitation on the heating value of burning gas and the pressure. Users can make a request as long as they order the goods.
- This burner is applied to positive pressure and negative pressure, and is also applied to the kiln that burn natural gas, city gas, liquefied petroleum gas and mine gas.
- We can also outfit some functions according to the users' demands, such as flameout protection,processing ignition, chase leaks, over temperature and excessive pressure protection and so on.
- Without the automatic system, manual operation can make normal combustion, and the accommodation is very easy.
|
| |
|
|
| |
|
| Type |
Design power(KW) |
Design fuel gas quantity(Nm3/h) |
Power regulation range(KW) |
Fuel gas quantity(Nm3/h) |
Electromotor power(KW) |
Adaptation to hearth back pressure (Pa) |
| DN15 |
200 |
20 |
59-248 |
6-25 |
1.0 |
<600 |
| DN30 |
350 |
36 |
110-515 |
11-52 |
1.5 |
<600 |
| DN60 |
700 |
70 |
200-990 |
20-100 |
2.2 |
<800 |
| DN150 |
1700 |
172 |
460-2000 |
46-202 |
3.0/4.0 |
<800/1000 |
| DN200 |
2300 |
232 |
580-3500 |
59-354 |
5.5/7.5 |
<1000/1200 |
| DN300 |
3000 |
300 |
930-4000 |
94-404 |
7.5/11 |
<1000/1200 |
| DN400 |
4200 |
424 |
1200-5740 |
121-580 |
18.5/22 |
<1200/1500 |
| DN600 |
7000 |
700 |
1700-8420 |
172-850 |
22/30 |
<1500/2000 |
| DN1200 |
14000 |
1400 |
4500-17000 |
455-1720 |
35/55 |
<1500/2000 |
| Annotation: we can design specially the product specification according to the user's request. |
|
| |
|
|
| |
|
- This burner is applied to negative pressure fuel gas kiln.
- The base construction adopts the composite mould of in-band and out-band.
- The same burner can burn stably and high efficiently in the range of 10%-150% designed rating. It can also meet the request.
- The fuel is natural gas, gas, liquefied petroleum gas and so on. When the voltage is between 0.04-0.4Mpa, it can burn stably.
- It can make the fuel oil negative pressure boiler burner realize to burn high efficiently without air blow.
- We can outfit flameout protection,processing ignition,self-regulation and chain control system demanded by the operation according to users' demands.
|
| |
|
|
| |
|
| Type |
Design pressure(KPa) |
Design power(KW) |
Design fuel gas quantity(Nm3/h) |
Power regulation range(KW) |
Fuel gas quantity(Nm3/h) |
| 1000kcl/h |
KW |
| NW4 |
0.05 |
4 |
50 |
5 |
10-90 |
1-9 |
| NW8 |
0.05 |
8 |
90 |
9 |
20-180 |
2-18 |
| NW15 |
0.05 |
15 |
170 |
17 |
30-350 |
3-35 |
| NW30 |
0.05 |
30 |
350 |
35 |
40-520 |
4-52 |
| NW50 |
0.05 |
50 |
580 |
59 |
59-870 |
5-88 |
| NW75 |
0.05 |
75 |
870 |
88 |
89-1300 |
9-131 |
| NW100 |
0.05 |
100 |
1160 |
116 |
118-1740 |
12-176 |
| NW120 |
0.05 |
120 |
1400 |
141 |
140-2080 |
14-210 |
| NW150 |
0.05 |
150 |
1740 |
176 |
175-2480 |
18-250 |
| NW200 |
0.05 |
200 |
2300 |
232 |
230-3370 |
23-340 |
| NW300 |
0.05 |
300 |
3480 |
352 |
348-5000 |
35-500 |
| NW400 |
0.05 |
400 |
4640 |
470 |
464-6000 |
47-600 |
| NW500 |
0.05 |
500 |
5800 |
586 |
580-7400 |
59-750 |
| NW600 |
0.05 |
600 |
7000 |
700 |
700-8900 |
70-900 |
| NW1000 |
0.05 |
1000 |
11600 |
1190 |
1160-16000 |
117-1600 |
| NW1200 |
0.05 |
1200 |
14000 |
1400 |
1400-19000 |
141-1900 |
|
| |
|
|
|
Long flame fuel gas burner |
|
| |
|
- Long flame fuel gas burner is an air blow fission fuel gas burner, which is minor diameter and long flame and is designed for the purpose of internally fired boiler.
- It employs a method that combines the in-band long position and wind scatter, and it can make sure the safe, stable and high efficient combustion.
- Automatic system contains various kinds of control modes, such as segmental fire type (air segmental fire control, frequency conversion segmental fire control), air sintering accommodation proportion type, frequency conversion accommodation type, touch screen digital frequency conversion accommodation proportion type and so on.
- Types of fuel: natural gas; city gas; liquefied petroleum gas and so on.
- There is no limitation on the heating value of burning gas and the pressure. Users can make a request as long as they order the goods.
- We can outfit flameout protection,processing ignition,self-regulation and chain control system demanded by the operation.
- Without the automatic system, manual operation can make normal combustion, and the accommodation is very easy.
|
| |
|
|
| |
|
| Type |
Design pressure(KPa) |
Design power(KW) |
Design fuel gas quantity(Nm3/h) |
Power regulation range(KW) |
Fuel gas quantity(Nm3/h) |
Flame diameter(mm) |
Flame length(m) |
| CDN100 |
12 |
1200 |
121 |
350-1700 |
35-172 |
250 |
1-1.5 |
| CDN200 |
12 |
2300 |
232 |
800-3500 |
81-354 |
300 |
1-1.28 |
| CDN300 |
12 |
3000 |
300 |
1200-4500 |
121-450 |
350 |
1-3.0 |
| CDN400 |
12 |
4200 |
424 |
1700-5450 |
172-550 |
400 |
1.5-3.5 |
| CDN600 |
12 |
7000 |
700 |
2300-8420 |
232-850 |
500 |
1.5-4.0 |
| Annotation: we can design specially the product specification according to the user's request. |
|
 |
|
|